Cryopump Repair
We provide expert cryopump repair and refurbishment services designed to restore your pumps to OEM specification reestablishing reliable performance.


Vacuum Side Service (Cryopump Rebuild)
Complete Disassembly & Cleaning
Full ultrasonic cleaning of all vacuum-side components
Inspect for manufacturing defects or damage not visible externally
Component Replacement
Charcoal array (15K condensing array) - the heart of cryogenic absorption
Indium gaskets and all O-rings
Inspection & Testing
80K condensing array (inlet array) - inspected, tested, replaced if capacity degraded
Radiation shields - verified for proper spacing and integrity
Hydrogen vapor gauge (if equipped) - calibrated or replaced
Temperature diode - inspected, tested, replaced if degraded
All internal surfaces checked for contamination or corrosion
Helium Side Service (Cryopump Rebuild)
Component Replacement
First and second stage displacer seals
Motor bearings and upper/lower bushings
Exhaust valve body
Springs and orings
Inspection & Testing
Scotch yoke mechanism - verified for smooth operation
Valve stems and rocker arms - inspected for wear
Crankshaft - checked for alignment and runout
Displacer assemblies - tested for seal integrity
Motor winding - remagnetized to restore efficiency
Inlet valve - inspected, cleaned, and tested for proper seating
Bench Test
Connect to test bench
Begin Regen
Run for 24 hours
Our Repair Service Scope
MODELS WE SERVICE
CTI On-Board Cryopumps
OB 4, OB 4F, OB 8, OB 8F, OB 10, OB 10F, OB 250F, OB 400, OB 500
CTI CryoTorr Cryopumps
CT4, CT4F, CT8, CT8F, CT10, CT10F, CT250F, CT400, CT500
CTI Helium Compressors
SC, 8200, 8300, 8500, 8510, 9600, 9700, 1020R
Leybold, Varian, Seiko Seiki, Balzers & Pfeiffer Turbo Pumps
Contact us with your specific model and we can provide a quote


QUALITY COMMITMENT
We don't just repair cryopumps - we restore them to meet or exceed OEM specifications.
Rigorous Testing Protocol
24-hour continuous operation test (minimum)
Multiple regeneration cycles under load
Temperature vs. pressure curve analysis (pumpdown curves recorded)
Helium leak testing (mass spectrometer sniff test)
RGA (Residual Gas Analysis) verification if requested
Warranty given with every rebuild
Contact Us
Support and inquiries welcome anytime.
Phone
sales@appliedcryogenics.com
1-510-252-9900
© 2026. All rights reserved.