Cryo Pump CTI
Cryo Pump CTI

Cryopump Repair

We provide expert cryopump repair and refurbishment services designed to restore your pumps to OEM specification reestablishing reliable performance.

Cryopump Repair
Cryopump Repair
15K Charcoal Array Kit
15K Charcoal Array Kit
Coldhead Rebuild Kit
Coldhead Rebuild Kit

Vacuum Side Service (Cryopump Rebuild)

Complete Disassembly & Cleaning

  • Full ultrasonic cleaning of all vacuum-side components

  • Inspect for manufacturing defects or damage not visible externally

Component Replacement

  • Charcoal array (15K condensing array) - the heart of cryogenic absorption

  • Indium gaskets and all O-rings

Inspection & Testing

  • 80K condensing array (inlet array) - inspected, tested, replaced if capacity degraded

  • Radiation shields - verified for proper spacing and integrity

  • Hydrogen vapor gauge (if equipped) - calibrated or replaced

  • Temperature diode - inspected, tested, replaced if degraded

  • All internal surfaces checked for contamination or corrosion

Helium Side Service (Cryopump Rebuild)

Component Replacement

  • First and second stage displacer seals

  • Motor bearings and upper/lower bushings

  • Exhaust valve body

  • Springs and orings

Inspection & Testing

  • Scotch yoke mechanism - verified for smooth operation

  • Valve stems and rocker arms - inspected for wear

  • Crankshaft - checked for alignment and runout

  • Displacer assemblies - tested for seal integrity

  • Motor winding - remagnetized to restore efficiency

  • Inlet valve - inspected, cleaned, and tested for proper seating

Bench Test

  • Connect to test bench

  • Begin Regen

  • Run for 24 hours

Our Repair Service Scope

MODELS WE SERVICE

CTI On-Board Cryopumps

OB 4, OB 4F, OB 8, OB 8F, OB 10, OB 10F, OB 250F, OB 400, OB 500

CTI CryoTorr Cryopumps

CT4, CT4F, CT8, CT8F, CT10, CT10F, CT250F, CT400, CT500

CTI Helium Compressors

SC, 8200, 8300, 8500, 8510, 9600, 9700, 1020R

Leybold, Varian, Seiko Seiki, Balzers & Pfeiffer Turbo Pumps

Contact us with your specific model and we can provide a quote

QUALITY COMMITMENT

We don't just repair cryopumps - we restore them to meet or exceed OEM specifications.

Rigorous Testing Protocol

24-hour continuous operation test (minimum)

Multiple regeneration cycles under load

Temperature vs. pressure curve analysis (pumpdown curves recorded)

Helium leak testing (mass spectrometer sniff test)

RGA (Residual Gas Analysis) verification if requested

Warranty given with every rebuild

Contact Us

Support and inquiries welcome anytime.

Email

Phone

sales@appliedcryogenics.com

1-510-252-9900

© 2026. All rights reserved.